An AI workstation or an AI server for your team.

An AI workstation such as NVIDIA DGX Station GB300 puts 252 GB of GPU memory beside a desk on a 20 A circuit, while an eight-GPU server such as NVIDIA DGX B200 holds 1,440 GB but draws up to about 14.3 kW of air-cooled load in a data center rack.

Wick Ultra sits between them: 1,152 GB of GPU memory, server class, in an office, lab or house, with its heat sent outside through its own outdoor unit.

See Wick Ultra

From $656,000Includes delivery, the outdoor unit and the first year of service.

Three classes side by side

NVIDIA's figures for its systems; Wick's from its published specifications.

Workstation, Wick Ultra and server
NVIDIA DGX Station GB300Wick UltraNVIDIA DGX B200
GPUs1 NVIDIA Blackwell Ultra4 NVIDIA Rubin8 NVIDIA B200
GPU memory252 GB1,152 GB1,440 GB
Power1,600 W11 kWAbout 14.3 kW
Where the heat goesInto the roomOutdoors; about 1.65 kW stays in the roomInto the room, 1,550 cubic feet of air a minute
FormDesktop towerLow fluted credenza, stacks two high10U rackmount, up to 142.4 kg
Where it livesA deskAn office, a lab or a houseA data center rack
PricePartner listings about $85,000 to $113,000From $656,000Not listed on NVIDIA's page

When a workstation is enough

One person, models that fit in one GPU's memory and a desk. DGX Station's 252 GB holds 4-bit weights up to about 504 billion parameters. Wick, from $199,000, is Wick's single-GPU system: 288 GB on one Rubin GPU, with its heat sent outside.

When a team needs server memory

A team that serves a frontier open model, or fine-tunes past a single GPU, needs several GPUs' memory in one system. Wick Ultra's 1,152 GB holds DeepSeek V4 Pro's 4-bit weights, about 800 GB. A Wick Cluster node holds 2,304 GB for training floors with three-phase power.

A rack server brings the same class of memory with data center needs: rack space, airflow and cooling sized for its full load. Wick sends its heat to its own outdoor unit, so the room needs an outside wall and a circuit.

Questions

What is the difference between an AI workstation and an AI server?

A workstation is built for one person at a desk, on an ordinary circuit, usually with one GPU. A server holds several GPUs for a team and is built for a data center's power and cooling: DGX B200 draws up to about 14.3 kW.

Can a server-class AI computer run in an office?

Yes, when its heat leaves the room. Wick Ultra draws 11 kW and sends nearly all of it outdoors, leaving about 1.65 kW in the room. Wick reviews your room with you before you accept a price.

Who sets up and services it?

Wick delivers it, fits the outdoor unit, connects power and network and switches it on. First year of service included in every list price.

Sources

  1. NVIDIA, DGX Station product page, observed October 27, 2026
  2. Tom's Hardware, DGX Station GB300 partner listings, 2026
  3. NVIDIA, DGX B200 specifications, observed October 27, 2026
  4. NVIDIA, DGX B200 user guide, observed October 27, 2026
  5. DeepSeek V4 Pro model card on Hugging Face, observed October 27, 2026

Wick figures are read from its published specifications and list prices. Checked October 27, 2026.